The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then publish the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 1: | Line 1: | ||
{{Host | {{Host | ||
|name=helios.chaosdorf. | |name=helios.chaosdorf.dn42 | ||
|description=almighty server | |description=almighty server | ||
|image=helios.jpg | |image=helios.jpg | ||
|os=Debian | |os=Debian 8 (jessie) | ||
|location= | |location=Serverraum | ||
|purpose=virtualization host | |purpose=virtualization host | ||
|disk= | |disk=8TB | ||
|ram=32GiB | |ram=32GiB | ||
|admin_toolkit=Yes | |admin_toolkit=Yes | ||
Line 12: | Line 12: | ||
|ssh_userlogin=No | |ssh_userlogin=No | ||
|ownership=club | |ownership=club | ||
|use= | |use=no | ||
|admins=derf, byte, nomaster, uen | |admins=derf, byte, nomaster, uen | ||
| | |mac=d0:50:99:2e:d1:28 | ||
}} | }} | ||
== Hardware == | == Hardware == | ||
* Mainboard: [http://www.asrockrack.com/general/productdetail.asp?Model=C2750D4I ASRock | * Mainboard: [http://www.asrockrack.com/general/productdetail.asp?Model=C2750D4I ASRock Mini-ITX mit 12x SATA] | ||
* CPU: [http://ark.intel.com/products/77987 Intel | * CPU: [http://ark.intel.com/products/77987 Intel Avoton C2750 8-Core] | ||
* Storage | * Storage: [http://www.wdc.com/global/products/specs/?driveID=1311&language=1 2x 1TB WD10JFCX Red] | ||
* RAM: 1x 32GB DDR3 1600MHz ECC | |||
* Gehäuse: 19" RM-236-8 2HE mit 8 Festplatteneinschüben | |||
* Netzteil: 400W EPS Green | * Netzteil: 400W EPS Green | ||
== Storage == | == Storage == | ||
Das Gehäuse bietet Platz für 10 | Das Gehäuse bietet Platz für 10 Platten, davon 2 intern (2.5") und 8 in Festplattenschächten (3.5"). | ||
Layout bei Aufsicht aufs Gehäuse: | Layout bei Aufsicht aufs Gehäuse: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
| | | (sys1) | ||
| | | (sys2) | ||
| | | | ||
| | | | ||
|- | |- | ||
| | | (vms1) | ||
| | | (storage1) | ||
| | | (storage3) | ||
| | | ''n.c.'' | ||
|- | |- | ||
| | | (vms2) | ||
| | | (storage2) | ||
| | | (storage4) | ||
| | | ''n.c.'' | ||
|} | |} | ||
=== Systemplatten === | === Systemplatten === | ||
Sind die beiden internen 2.5"-Platten ( | * sys1: ??? | ||
* sys2: ??? | |||
Sind die beiden internen 2.5"-Platten. Jeweils 1TB Western Digital Red (WDC WD10JFCX-68N6GN0). Auf beiden Platten befinden sich vier Partitionen á 250GB, die wie folgt genutzt werden. | |||
* 1. Partition: RAID 1 für / | |||
* 2. Partition: Wird nicht benutzt | |||
* 3. Partition: RAID 1 für <tt>helios0-backup</tt> (Backup der VM-Images von hyperion) | |||
* 4. Partition: Wird nicht benutzt | |||
=== VM-Platten === | |||
* vms1: Hitachi Deskstar 7K2000 HDS722020ALA330 (wwn-0x5000cca222c96707) | |||
* vms2: Hitachi Deskstar 7K2000 HDS722020ALA330 (wwn-0x5000cca221c5cc76) | |||
Jeweils 2TB Hitachi Deskstar 7K2000 (HDS722020ALA330). Enthalten noch die Partitionen von hyperion, verwendet wird nur die dritte (1.7TB RAID1). Darauf liegt die VG <tt>hyperion0</tt>, welche wiederum LVs für die einzelnen VMS enthält. | |||
=== Storage === | === Storage === | ||
* storage1: Hitachi Deskstar 7K2000 HDS722020ALA330 (wwn-0x5000cca221c5cc70) | |||
* storage2: Seagate Barracuda 7200.14 ST2000DM001-1CH164 (wwn-0x5000c500538e357f) | |||
Je 2TB. Die Platten sind ohne Partitionen zu einem RAID1 zusammengebunden, darauf befindet sich ein LUKS-Container (UUID <tt>85a95dea-a9aa-748d-99b8-c6a972a9e1e4</tt> bzw. <tt>/dev/mapper/storage</tt>). Dieser wird an die VM fileserver durchgereicht. | |||
=== Storage === | |||
* todo | |||
* todo | |||
Je 3TB. Die Platten sind ohne Partitionen zu einem RAID1 zusammengebunden, der Rest folgt noch. | |||
== Netzwerk == | == Netzwerk == | ||
Line 96: | Line 114: | ||
== Virtuelle Maschinen == | == Virtuelle Maschinen == | ||
{{#ask: [[Has location::Host:Helios | {{#ask: [[Has location::Host:Helios]] | ||
| ?Hostname | | ?Hostname | ||
| ?Operating System | | ?Operating System | ||
| ?Disk size | | ?Disk size | ||
| ?RAM size | | ?RAM size | ||
}} | }} | ||
== IPMI == | == IPMI == | ||
Line 138: | Line 137: | ||
=== Serial over LAN === | === Serial over LAN === | ||
ttyS1 ist per IPMI nutzbar. BIOS geht darüber auch | ttyS1 ist per IPMI nutzbar. BIOS geht darüber auch. | ||
=== Watchdog === | === Watchdog === | ||
Das Mainboard hat einen IPMI (SMS/OS) Watchdog. Der Daemon '''bmc-watchdog''' setzt diesen alle 60 Sekunden zurück. Falls er nicht läuft, wird automatisch nach 15 Minuten ein hard reset ausgelöst. | Das Mainboard hat einen IPMI (SMS/OS) Watchdog. Der Daemon '''bmc-watchdog''' setzt diesen alle 60 Sekunden zurück. Falls er nicht läuft, wird automatisch nach 15 Minuten ein hard reset ausgelöst. | ||
== Verstärkersteuerung == | |||
Per USB ist die [[Verstärkerschaltung]] angeschlossen. Zur Anbindung an die [[Lichtsteuerung]] läuft ein Netzwerkdienst per systemd, der auf Port 1338 Befehle an die Schaltung weiterleitet. Es handelt sich dabei um das graue USB-Kabel. | |||
Abgesehen von der Fernsteuerung und einem munin-Graphen enthält der Host keine Steuerlogik für die Verstärker. |