Editing Archiv:Unterverteilung

From Chaosdorf Wiki
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then publish the changes below to finish undoing the edit.

Latest revision Your text
Line 3: Line 3:
|description=power distribution
|description=power distribution
|location=WC mit Pissoir
|location=WC mit Pissoir
|resource category=Infrastruktur
|preview image=Yes
|ownership=club
|ownership=club
|contactnick=ragnar
|contactnick=ragnar
Line 9: Line 9:
|broken=notify
|broken=notify
|annoying=notify
|annoying=notify
|has label=No
|preview image=Yes
}}
}}
{{#set:Has maximum power=43470W}}
[[File:Grundriss Strom.png|300px|thumb|right|Warum liegt denn da Strom rum?]]
[[File:Sicherungskasten oben 20121130.jpeg |300px|thumb|right|strace]]
[[File:Sicherungskasten unten 20121130.jpeg|300px|thumb|right|truss]]
Derzeitiger Aufbau unserer Unterverteilung. Im Zweifelsfall natürlich immer nachprüfen/messen.
Derzeitiger Aufbau unserer Unterverteilung. Im Zweifelsfall natürlich immer nachprüfen/messen.


Mit "unbekannt" markierte Automaten sind verbunden, aber aus, und bleiben besser auch aus. "nicht verbunden" sind im Kasten nicht angeschlossen.
Mit "unbekannt" markierte Automaten sind verbunden, aber aus, und bleiben besser auch aus. "nicht verbunden" sind im Kasten nicht angeschlossen.


Siehe auch: [[Maschinenraum/Strom|Strom im Maschinenraum]] (Schalter befindet sich links unten über dem Hauptschalter und ist beschriftet).
'''Stand: 16.08.2012'''


'''Stand: 30.11.2012'''
{| class="wikitable"
 
! Nr !! Wat                                            !! Type of
== Automaten ==
 
Im Sicherungskasten im Hausflur befinden sich drei 50A Schmelzsicherungen, von dort aus geht die Zuleitung zu unserem Kasten.
 
{| class="wikitable sortable"
! Nr !! L  !! Wat                                            !! Type of
|-
|  1 || L1 || WC Herren                                      || Licht, Steckdose
|-
|  2 || L2 ||  WC Damen                                      || Licht
|-
|  3 || L3 ||  Transporterraum, Raucherraum, Durchgang        || Licht, Steckdose
|-
|  4 || L1 ||  Serverraum                                    || Licht
|-
|  5 || L2 ||  Dusche                                        || Licht
|-
|  6 || L3 ||  Küche + Küchenlager                            || Licht
|-
|  7 || L1 ||  Küchenregal                                    || Steckdose
|-
|  8 || L2 ||  Backofen                                      || Steckdose
|-
|  9 || L3 ||  Notbeleuchtung Maschinenraum                  || Licht
|-
| 10 || L1 ||  Nomspace                                      || Licht
|-
| 11 || L2 ||  Kabelkanal Treppe, 1. Dose von hinten          || Steckdose
|-
| 12 || L3 ||                                                || nicht verbunden
|-
|-
| 13 || L1 || Hackcenter Heizung                            || Steckdose
| 1 || WC Herren                                      || Licht, Steckdose
|-
|-
| 14 || L2 || Nomspace (Mete-Tablet, Dreierdose etc)        || Steckdose
| 2 || WC Damen                                      || Licht
|-
|-
| 15 || L3 || Hackcenter Spiegel                            || Steckdose
| 3 || Transporterraum, Raucherraum, Durchgang, Licht über Kühlschrank || Licht, Steckdose
|-
|-
| 16 || L1 || Hackcenter Drucker                            || Steckdose
| 4 || Serverraum                                    || Licht
|-
|-
| 17 || L2 || Tür (Dockstar/Motor)                          || Steckdose
| 5 || Dusche                                        || Licht
|-
|-
| 18 || L3 || Treppe links/Garderobe, Bikeshed              ||
| 6 || Küche + Küchenlager                            || Licht
|-
|-
| 19 || L1 || Treppe rechts/Geländer                        ||
| 7 || Küchenregal                                    || Steckdose
|-
|-
| 20 || L2 || Hackcenter Bücherregal                        ||
| 8 || Backofen                                      || Steckdose
|-
|-
| 21 || L3 || Lounge Fenster                                || Steckdose
| 9 || Maschinenraum                                  || Licht, Steckdose
|-
|-
| 22 || L1 || Kabelkanal lang (Freifunk)                    || Steckdose
| 10 ||                                               || nicht verbunden
|-
|-
| 23 || L2 ||  Kabelkanal Treppe, 3. Dose von hinten          || Steckdose
| 11 || Kabelkanal Treppe, 1. Dose von hinten          || Steckdose
|-
|-
| 24 || L3 || Serverraum
| 12 ||                                               || nicht verbunden
|-
|-
| 25 || L1 || Kabelkanal Treppe, 2. Dose von hinten
| 13 || Hackcenter Heizung                            || Steckdose
|-
|-
| 26 || L2 || Kabelkanal lang vorne (falsch mit (X) beschriftet)
| 14 || Nomspace (Kühlschrank, Dreierdose etc)        || Steckdose
|-
|-
| 27 || L3 || Kabelkanal lang                                || unbekannt
| 15 || Hackcenter Spiegel                            || Steckdose
|-
|-
| 28 || L1 ||  nomspace Decke (Kühlschrank)                  || Steckdose
| 16 || Hackcenter Drucker/Ex-Lötecke                  || Steckdose
|-
|-
| 29 || L2 ||                                                 || nicht verbunden
| 17 || Tür (Dockstar/Motor)                          || Steckdose
|-
|-
| 30 || L3 ||                                                 || nicht verbunden
| 18 || Treppe links/Garderobe, Bikeshed              ||
|-
|-
| 31 || L1 ||                                                 || nicht verbunden
| 19 || Treppe rechts/Geländer                        ||
|-
|-
| 32 || L2 || Deckenbeleuchtung Hauptraum + 12V Trafo        || Licht
| 20 || Hackcenter Bücherregal                        ||
|-
|-
| 33 ||   ||                                                || unbekannt
| 21 || Lounge Fenster
|-
|-
| 34 ||   ||                                                || unbekannt
| 22 || Kabelkanal lang (Wifi, 1. Dose von vorn, evtl Rest)
|-
|-
| 35 ||   ||                                                 || nicht verbunden
| 23 ||                                               || unbekannt
|-
|-
| 36 ||   ||                                                || nicht verbunden
| 24 || Serverraum
|-
|-
| 37 ||   ||                                                || nicht verbunden
| 25 || Kabelkanal Treppe, 2. Dose von hinten
|-
|-
| 38 || L1
| 26 || Kabelkanal lang vorne (falsch mit (X) beschriftet)
| rowspan="3" | Durchlauferhitzer
| rowspan="3" |
|-
|-
| 39 || L2
| 27 ||                                               || unbekannt
|-
|-
| 40 || L3
| 28 ||                                               || unbekannt
|}
 
== FIs ==
 
Haben wir. Sind regelmäßig zu testen. <del>FI 2 sollte nur in einer scheduled Downtime des Serverraums getestet werden.</del>
 
=== FI Testdoku ===
{| class="wikitable"
! Datum      !! FI 1 !! FI 2 !! [[Maschinenraum/Strom|FI 3]] !! Kommentar
|-
|-
| 27.08.2014 || X    || X    ||                              ||
| 29 ||                                               || nicht verbunden
|-
|-
| 28.10.2014 || X    ||      ||                              ||
| 30 ||                                               || nicht verbunden
|-
|-
| 23.11.2014 || X    || X    || X                            || Test mit einem BEHA Unitest 0100-Expert plus - die Auslösezeit war in Ordnung
| 31 ||                                               || nicht verbunden
|-
|-
| 05.02.2016 ||      || X    ||                              || Kaputtes Netzteil \o/
| 32 || Deckenbeleuchtung Hauptraum + 12V Trafo       || Licht
|}
 
== Relais ==
 
Oben rechts direkt neben dem 12V-Trafo (dieser liefert die Steuerspannung). Sowohl der Trafo als auch der geschaltete Strom liegt an Sicherung 32.
 
Relais 1 klebt und geht nicht zuverlässig aus.
 
{| class="wikitable"
! Nr  !! Wtf
|-
|-
| || -
| 33 ||                                               || unbekannt
|-
|-
| || -
| 34 ||                                               || unbekannt
|-
|-
| || -
| 35 ||                                               || nicht verbunden
|-
|-
| || Kabelkanal Hackcenter (unbekannt, nichts angeschlossen)
| 36 ||                                               || nicht verbunden
|-
|-
| || Beleuchtung Lounge (grüne LEDs)
| 37 ||                                               || nicht verbunden
|}
|}


== Flukso ==
[[Has location::WC mit Pissoir| ]]
 
{{H|flukso}} steht über dem Sicherungskasten und wird über den 12V-Trafo versorgt. Die Messklemmen hängen an der Zuleitung vom Haus-Sicherungskasten im Flur, vor unserem Hauptschalter und vor der Verzweigung zum [[Maschinenraum/Strom|Maschinenraum]].
 
Es handelt sich um Hallsensoren, ein Betrieb ohne angeschlossenen / eingeschalteten Flukso ist also ungefährlich.
 
== Stromverbrauch nach Sicherung ==
 
Bei unbelastetem Chaosdorf.
 
{| class="wikitable sortable"
! Nr !! L  !! Datum !! Verbrauch [W] !! Kommentar
|-
|  1 || L1 || 2013-12-07 ||  0 || Klo. Licht und Lüfter sind 250W
|-
|  2 || L2 || 2013-12-07 ||  0 || Klo
|-
|  3 || L3 || 2013-12-07 ||  0 ||
|-
|  4 || L1 || 2013-12-07 ||  0 ||
|-
|  5 || L2 || 2013-12-07 ||  0 ||
|-
|  6 || L3 || 2013-12-07 ||  0 || Licht 120W
|-
|  7 || L1 || 2013-12-07 ||  0 ||
|-
|  8 || L2 || 2013-12-07 ||  3 ||
|-
|  9 || L3 || 2013-12-07 ||  0 ||
|-
| 11 || L2 || 2013-12-07 ||  0 ||
|-
| 12 || L3 || 2013-12-07 ||  0 ||
|-
| 13 || L1 || 2013-12-07 ||  60 || Switch 25W, Licht Tisch 5W, Makerbot 5W, NES Bildschirm 5W, NES 20W
|-
| 14 || L2 || 2013-12-07 ||  5 || Nur mete-Tablet?
|-
| 15 || L3 || 2013-12-07 ||  0 ||
|-
| 16 || L1 || 2013-12-07 ||  90 || Steckerleiste links vom Drucker 10W, RIP 20W, Drucker 60W (im Poweroff?! -> ausgesteckt)
|-
| 17 || L2 || 2013-12-07 ||  45 ||
|-
| 18 || L3 || 2013-12-07 ||  0 ||
|-
| 19 || L1 || 2013-12-07 ||  0 ||
|-
| 20 || L2 || 2013-12-07 ||  70 || Dashpi Display 20W (Bild anzeigend), Fernseher softoff 1W (30VA?), Leucht+Raspi+Tisch 20W
|-
| 21 || L3 || 2013-12-07 ||  10 ||
|-
| 22 || L1 || 2013-12-07 ||  0 ||
|-
| 23 || L2 || 2013-12-07 ||  0 ||
|-
| 25 || L1 || 2013-12-07 ||  0 ||
|-
| MR ||  || 2013-12-07 ||  0 ||
|-
|}
 
In Summe 280. Dazu unbekannter Verbrauch von Kühlschränken.
 
Serverraum USV Eingang: 190W/245VA