Editing Modbus protokoll rs485

From Chaosdorf Wiki
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then publish the changes below to finish undoing the edit.

Latest revision Your text
Line 35: Line 35:


<br>
<br>
adr  -> device Adress oder auch UID - 1 Byte lang <br>
adr  -> device Adress 1 Byte <br>
fc  -> Function Code 1 Byte <br>
fc  -> Function Code 1 Byte <br>
data -> n Bytes<br>
data -> n Bytes<br>
 
* das sind wohl noch nicht alle Modbus Funktion Code
 
=== Modbus Rtu 2 ===
 
Hardware Resources:
Data register address
  *  RS485 communication interface
  *  TTL communication interface
  *  2 optocoupler isolation input
  *  2 way optocoupler isolation output
  *  A user button
  *  A user LED
  *  A power indicator
  *  A STM32F030F4 microcontroller
  *  2 relay status indicators LED lights
  *  Power supply terminal interface (12V power supply)
 


Modbus RTU Instructions:
Modbus RTU Instructions:
Line 50: Line 68:
2. Set the address (communication using the device address, the default address is 01)<br>
2. Set the address (communication using the device address, the default address is 01)<br>
<br>
<br>
Set the address from from Broadcast to 0x01 , 0x02 , 0x03
Set the address from 01 to 09 or from Broadcast to 09
 


{| class="wikitable"
{| class="wikitable"
Line 64: Line 83:
<br>
<br>


Read Address at Broadcast Call <br>
 
Read Address<br>


{| class="wikitable"
{| class="wikitable"
Line 70: Line 90:
! Hex Byte  !! Funktion   
! Hex Byte  !! Funktion   
|-
|-
| 00 03 00 00 00 01 85 db  || Send to Device ( Broadcast )
| 00 03 00 00 00 01 85 db  || Send to Device
|-
|-
| 00 03 02 00 01 44 44    || Receive from Device  '''01 for Address'''
| 00 03 02 00 01 44 44    || Receive from Device  '''01 for Address'''
Line 76: Line 96:
| 00 03 02 00 02 04 45    || Receive from Device  '''02 for Address'''
| 00 03 02 00 02 04 45    || Receive from Device  '''02 for Address'''
|-
|-
| 00 03 02 00 03 C5 85     || Receive from Device  '''03 for Address'''
|00 03 02 00 03 C5 85     || Receive from Device  '''03 for Address'''
|-
|-
|}
|}
<br>
=== Modbus Rtu 2 ===
Hardware Resources:
Data register address
  *  RS485 communication interface
  *  TTL communication interface
  *  2 Input ( max. DC +12 Volt UB )
  *  2 Relay Output
  *  A user button
  *  A user LED
  *  A power indicator
  *  A STM32F030F4 microcontroller
  *  2 relay status indicators LED lights
  *  Power supply terminal interface (12V power supply)


Meaning of each byte:<br>
Meaning of each byte:<br>
Line 108: Line 111:




[address 1 bzw. UID 0x01]<br>
[address 1]<br>


Switch Single  
Switch Single  
Line 121: Line 124:
| 01      || 05        ||  00  ||    00  ||    00  ||  00    ||    CD  ||  CA  ||  0 relay off   
| 01      || 05        ||  00  ||    00  ||    00  ||  00    ||    CD  ||  CA  ||  0 relay off   
|-
|-
| 01      || 05        ||  00  ||    01  ||    FF  ||  00    ||    DD  ||  FA  ||  1 relay ON  
| 01      || 05        ||  00  ||    01  ||    FF  ||  00    ||    DD  ||  FA  ||  No. 1 relay ON  
|-
|-
| 01      || 05        ||  00  ||    01  ||    00  ||  00    ||    9C  ||  0A  ||  1 relay off
| 01      || 05        ||  00  ||    01  ||    00  ||  00    ||    9C  ||  0A  ||  No. 1 relay off
|-
| 01      || 05        ||  00  ||    02  ||    FF  ||  00    ||    2D  ||  FA  ||  No. 2 relay ON
|-
| 01      || 05        ||  00  ||    02  ||    00  ||  00    ||    6C  ||  0A  ||  No. 2 relay off
|-
|-
|}
|}




all Funktion
Switch all


{| class="wikitable"
{| class="wikitable"
Line 135: Line 142:
| Adresse  || Funktion  || Reghigh || Reglow || Data 1 || Data 2 || Data 3 || Data 4 || CRChigh || CRClow || Funktion   
| Adresse  || Funktion  || Reghigh || Reglow || Data 1 || Data 2 || Data 3 || Data 4 || CRChigh || CRClow || Funktion   
|-
|-
| 01      || 0F        ||  00  ||    00  ||    00  ||  08  ||    01  ||  00  ||  FE    || 95    || Full Relay off
| 01      || 0F        ||  00  ||    00  ||    00  ||  08  ||    01  ||  00  ||  FE    || 95    || Full off
|-
|-
| 01      || 0F        ||  00  ||    00  ||    00  ||  08  ||    01  ||  FF  ||  BE    || D5    || Full Relay on
| 01      || 0F        ||  00  ||    00  ||    00  ||  08  ||    01  ||  FF  ||  BE    || D5    || Full on
|-
|          ||          ||        ||        ||        ||        ||        ||        ||        ||        ||
|-
| 01      || 01        ||  00  ||    00  ||    00  ||  08  ||        ||        ||  BE    || D5    || Send : Read all relay states
|-
| 01      || 01        ||  01  ||    00  ||        ||        ||        ||        ||  51    || 88    || Return : Relay fully closed
|-
| 01      || 01        ||  01  ||    03  ||        ||        ||        ||        ||  11    || 89    || Return : All relays are on
|-
|-
|          ||          ||        ||        ||        ||        ||        ||        ||        ||        ||  
|          ||          ||        ||        ||        ||        ||        ||        ||        ||        ||  
Line 148: Line 163:


Quelle - https://hacktronics.co.in/2-channel-relay-module/modbus-rtu-2-way-relay-output-2-way-input-switch-ttl-rs485-interface-communication
Quelle - https://hacktronics.co.in/2-channel-relay-module/modbus-rtu-2-way-relay-output-2-way-input-switch-ttl-rs485-interface-communication
<br>


=== Modbus Rtu 4 ===
=== Modbus Rtu 4 ===
Line 159: Line 170:
   *  RS485 communication interface
   *  RS485 communication interface
   *  TTL communication interface
   *  TTL communication interface
   *  4 Input ( Switch to GND !!!! NO + UB !!! )
   *  4 optocoupler isolation input
   *  4 Relay Output
   *  4 way optocoupler isolation output
   *  2 user button
   *  A user button
   *  A user LED
   *  A user LED
   *  A power indicator
   *  A power indicator
Line 169: Line 180:




Modbus RTU command


[address 1 bzw. UID 0x01]<br>
Baud Rate: 9600 8 NONE 1
 
Switch Single


{| class="wikitable"
{| class="wikitable"
! colspan="8"| Hex Data !! colspan="1"| Funktion
|-
|-
| Adresse || Funktion  || Reghigh || Reglow || Data 1 || Data 2 || CRChigh || CRClow || Funktion   
! Hex Byte !! Funktion   
|-
|-
| 01      || 05        ||  00   ||    00   ||    FF  ||  00     ||    8C || 3A  ||  0 relay ON
| 00 06 40 00 00 01 5c 1b || Setting address is: 01
|-
|-
| 01      || 05        ||  00   ||    00  ||    00   ||  00     ||    CD || CA  ||  0 relay off 
| 00 06 40 00 00 02 1c 1a || Setting address is: 02
|-
|-
| 01      || 05        ||  00   ||    01   ||    FF  ||  00    ||    DD || FA  ||  1 relay ON
| 00 03 40 00 00 01 90 1b || Read address
|-
|-
| 01      || 05        ||  00  ||    01  ||    00  ||  00    ||    9C  ||  0A  ||  1 relay off
|                         || Read the software version
|-
|-
| 01      || 05        ||  00   ||    02  ||    FF  ||  00     ||    xx ||  xx  ||  2 relay ON
| 00 03 00 04 00 01 c4 1a ||  [month] broadcast read (only by one device to address all practical, easy to test)
|-
|-
| 01      || 05        ||  00  ||    02  ||    00  ||  00    ||    xx  ||  xx || 2 relay off
|  ||Read the hardware version (PCB version)
|-
|-
| 01      || 05        ||  00   ||    03   ||    FF  ||  00     ||    xx  ||  xx  ||  3 relay ON
| 00 03 00 04 00 01 c4 1a ||  broadcast read (only by one device to address all practical, easy to test)
|-
| 01       || 05        ||  00  ||    03  ||    00  ||  00    ||    xx  ||  xx ||  3 relay off
|-
|-
|}




[address 1]<br>


{| class="wikitable"
|-
! Hex Byte  !! Funktion 
|-
| 01 05 00 01 01 00 9d 9a || No. 1 relay ON
|-
| 01 05 00 01 00 00 9c 0a || No. 1 relay off
|-
|    ||
|-
| 01 05 00 02 01 00 6d 9a || No. 2 relay ON
|-
| 01 05 00 02 00 00 6c 0a || No. 2 relay off
|-
|    ||
|-
| 01 05 00 03 01 00 3c 5a || No. 3 relay ON
|-
| 01 05 00 03 00 00 3d ca || No. 3 relay off
|-
|    ||
|-
| 01 05 00 04 01 00 8d 9b || No. 4 relay ON
|-
| 01 05 00 04 00 00 8c 0b || No. 4 relay off
|-
|    ||
|-
| 01 05 00 ff 00 00 fd fa || Quanmie
|-
| 01 05 00 ff ff ff fc 4a || All light
|}


[address 2]<br>


{| class="wikitable"
|-
! Hex Byte  !! Funktion 
|-
| 02 05 00 01 01 00 9d a9 || No. 1 relay ON
|-No. 1 relay 1 channel status
| 02 05 00 01 00 00 9c 39 || No. 1 relay off
|-
|    ||
|-
| 02 05 00 02 01 00 6d a9 || No. 2 relay ON
|-
| 02 05 00 02 00 00 6c 39 || No. 2 relay off
|-
|    ||
|-
| 02 05 00 03 01 00 3c 69 || No. 3 relay ON
|-
| 02 05 00 03 00 00 3d f9 || No. 3 relay off
|-
|    ||
|-
| 02 05 00 04 01 00 8d a8 || No. 4 relay ON
|-
| 02 05 00 04 00 00 8c 38 || No. 4 relay off
|-
|    ||
|-
| 02 05 00 ff 00 00 fd c9 || Quanmie
|-
| 02 05 00 ff ff ff fc 79 || All light
|}
|}
 
<br>
 
[address 1]<br>
all Funktion
 
{| class="wikitable"
{| class="wikitable"
! colspan="8"| Hex Data !! colspan="1"| Funktion  
|-<gallery>
<small>Small text</small
! Hex Byte  !! Funktion
|-
|-
| Adresse  || Funktion  || Reghigh || Reglow || Data 1 || Data 2 || Data 3 || Data 4 || CRChigh || CRClow || Funktion 
| 01 01 00 01 00 04 6c 09 || Send : No. 1 relay 1 channel status
|-
|-
| 01      || 0F        ||  00  ||    00  ||    00  ||  08  ||    01  ||  00  ||  FE    || 95    || Full Relay off
| || Return ......
|-
|-
| 01       || 0F        ||  00   ||    00   ||    00  ||  08  ||    01  ||  FF  ||  BE    || D5    || Full Relay on
| 01 01 00 02 00 04 9c 09 || Send : No. 1 Relay 2 channel status
|-
|-
|         ||          ||        ||        ||        ||        ||        ||        ||        ||        ||  
| || Return ......
|-
|-
| 01     || 02        ||  00   ||  00    ||  00   ||  08    ||        ||        ||  79    || CC    || Send : Read all input switch status  
| 01 01 00 03 00 04 CD C9 || Send : No. 1 Relay 3 channel status
|-
|-
| 01      || 02        ||  01    ||  00    ||        ||        ||        ||        ||  A1    || 88    || Return : 8 input states
| || Return ......
|-
|-
| 01 01 00 04 00 04 7C 08 || Send : No. 1 Relay 4 channel status
|}
|}


<br>
<br>


[https://hacktronics.co.in/4-channel-relay-module/4-channel-relay-module-programmable-w-opto-isolated-rs485-stm8s103f3 hacktronics.co.in/4-channel-relay-module]
[https://hacktronics.co.in/4-channel-relay-module/4-channel-relay-module-programmable-w-opto-isolated-rs485-stm8s103f3 hacktronics.co.in/4-channel-relay-module]
Please note that all contributions to Chaosdorf Wiki are considered to be released under the Attribution 3.0 Unported (see Chaosdorf Wiki:Copyrights for details). If you do not want your writing to be edited mercilessly and redistributed at will, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource. Do not submit copyrighted work without permission!
Cancel Editing help (opens in new window)